PT-2026-148864
CVE-2026-124645
·
Published
2026-11-17
·
Updated
2026-11-19
Description by
CVSS 4.0
8.7
HighMetricsAV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
This vulnerability exists in e-Sushrut HIMS due to the use of a static and predictable value in the client-side password hashing mechanism, which is embedded in the login page and accessible to unauthenticated users. An unauthenticated remote attacker could exploit this vulnerability by accessing the login page, extracting the embedded value and using it to reproduce the password hashing process.
Successful exploitation of this vulnerability could weaken the security of the authentication mechanism and potentially facilitate authentication related attacks on the targeted healthcare organization.
Found an issue in the description? Have something to add? Feel free to write us 👾