PT-2026-37084

CVE-2026-7865

·

Published

2026-05-05

·

Updated

2026-05-08

Description by

CVSS 4.0
7.4
High
MetricsAV:N/AC:H/AT:N/PR:H/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Name of the Vulnerable Software and Affected Versions Crestron devices (affected versions not specified)
Description A hidden console command contains a command injection flaw occurring when control characters are passed to its second argument. This issue exists in the way the console command is passed to the popen() function. Authenticated attackers with SSH console access can exploit this to execute underlying operating system commands.
Recommendations At the moment, there is no information about a newer version that contains a fix for this vulnerability.
Impacts
Researchers
Vendors
Affected products
Related identifiers