PT-2026-4356 · Schneider Electric · Ecostruxure Process Expert

CVE-2025-13905

·

Published

2026-01-13

·

Updated

2026-01-29

CVSS v4.0

7.0

High

VectorAV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Name of the Vulnerable Software and Affected Versions Schneider Electric EcoStruxure Process Expert versions prior to 2025
Description An incorrect default permissions issue can lead to privilege escalation via a reverse shell. A local user with normal privileges can modify executable service binaries within the installation folder, potentially gaining elevated access upon service restart. This poses a risk to critical manufacturing and energy sectors.
Recommendations Update to version 2025. Apply application whitelisting.

Fix

LPE

Incorrect Default Permissions

Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

BDU:2026-01773
CVE-2025-13905

Affected Products

Ecostruxure Process Expert