PT-2026-61708 · Vsee · Clinic+1

·

CVE-2026-13381

·

Published

2026-07-20

·

Updated

2026-08-14

CVSS v4.0

8.7

High

VectorAV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Name of the Vulnerable Software and Affected Versions VSee Clinic version 7.1.26 VSee API version 1.3.0
Description An Insecure Direct Object Reference (IDOR) occurs in the '/v1.3.0/api/files' endpoint. An authenticated attacker can manipulate the remark request parameter to enumerate, retrieve, and delete files belonging to other users on the application server. IDOR is a type of access control flaw where an application provides direct access to objects based on user-supplied input.
Recommendations At the moment, there is no information about a newer version that contains a fix for this vulnerability. Avoid using the remark parameter in the '/v1.3.0/api/files' endpoint until the issue is resolved.

IDOR

Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

CVE-2026-13381

Affected Products

Clinic
Clinic Api