PT-2026-71336 · Mongodb · Mongodb Bi Connector Odbc Driver
CVE-2026-19003
·
Published
2026-08-12
·
Updated
2026-08-13
CVSS v4.0
8.4
High
| Vector | AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N |
Name of the Vulnerable Software and Affected Versions
MongoDB BI Connector ODBC Driver (affected versions not specified)
Description
A buffer overflow occurs in the setup dialog when a data source definition contains an over-length file path setting. This is caused by an incorrect buffer capacity calculation during file and folder selection handling. The issue is triggered when a user opens the setup dialog for an affected data source and initiates a file or folder selection. This may lead to abnormal process termination or the execution of unintended code within the context of the user running the dialog.
Recommendations
At the moment, there is no information about a newer version that contains a fix for this vulnerability.
Exploit
Stack Overflow
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Mongodb Bi Connector Odbc Driver