PT-2026-82303 · Comfast · Cf-N1-S+1

CVE-2026-75364

·

Published

2026-08-26

·

Updated

2026-08-31

CVSS v3.1

6.8

Medium

VectorAV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions Comfast CF-N1-S version 2.6.0.1 Comfast CF-WR630AX version 2024-01-30 build
Description The update interface png SET handler in /usr/bin/webmgnt fails to sanitize the display name parameter. User-controlled input is concatenated via sprintf() into the unquoted shell command /etc/rrd/graphinterface %s %s and executed by system() with root privileges. This allows a remote authenticated attacker to inject and execute arbitrary commands.
Recommendations At the moment, there is no information about a newer version that contains a fix for this vulnerability.

Exploit

OS Command Injection

Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

CVE-2026-75364

Affected Products

Cf-N1-S
Cf-Wr630Ax