PT-2026-87096 · Netis Systems · Nx10

·

CVE-2026-61517

·

Published

2026-09-08

·

Updated

2026-09-08

CVSS v3.1

7.2

High

VectorAV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Netis NX10 firmware V4.0.1.5808 and V3.0.0.4142 contain an OS command injection vulnerability in the ping diagnostic handler that allows authenticated administrators to execute arbitrary shell commands as root by injecting into the IpAddr parameter. The parameter is interpolated directly into a shell command executed through system() with an incomplete denylist that only blocks spaces, pipes, semicolons, and ampersands, leaving command substitution and alternate field separator expansion available for exploitation.

Exploit

Fix

OS Command Injection

Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

CVE-2026-61517

Affected Products

Nx10