PT-2026-90396
CVE-2026-89680
·
Published
2026-09-11
·
Updated
2026-11-19
Description by
CVSS 3.1
7.5
HighMetricsAV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Name of the Vulnerable Software and Affected Versions
Linux kernel versions prior to 7.2.6-1.1
Description
A resource leak occurs in the nfsd component during an inter-server COPY setup failure. When the function
nfsd4 setup inter ssc() fails, the nfsd4 copy() function returns an error directly, bypassing the cleanup process handled by release copy files(). This prevents the release of the nf dst reference created by nfs4 preprocess stateid op(), resulting in the leak of one nfsd file per failed operation, which pins the file, inode, dentry, and vfsmount.Recommendations
Update to version 7.2.6-1.1.
Found an issue in the description? Have something to add? Feel free to write us 👾