PT-2026-95507

CVE-2026-93338

·

Published

2026-09-18

·

Updated

2026-11-13

Description by

CVSS 3.1
5.3
Medium
MetricsAV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Name of the Vulnerable Software and Affected Versions Grandstream GWN7660ELR versions prior to 1.0.27.6
Description An information disclosure issue exists where unauthenticated remote attackers can obtain sensitive system information by querying the SNMP v2c service when it is configured with the default community string public. By querying standard MIBs (Management Information Bases, which are hierarchical databases used for managing entities in a network), attackers can retrieve the operating system and kernel version, running process names and command-line arguments, network interface configuration, routing table entries, ARP table mappings, active TCP connection details, and file system paths. This allows for detailed reconnaissance of the device and the adjacent network infrastructure.
Recommendations Update Grandstream GWN7660ELR to firmware version 1.0.27.6 or later. Change the default SNMP community string from public to a secure value. Restrict access to the SNMP service to authorized management stations.