PT-2026-95507
CVE-2026-93338
·
Published
2026-09-18
·
Updated
2026-11-13
Description by
CVSS 3.1
5.3
MediumMetricsAV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Name of the Vulnerable Software and Affected Versions
Grandstream GWN7660ELR versions prior to 1.0.27.6
Description
An information disclosure issue exists where unauthenticated remote attackers can obtain sensitive system information by querying the SNMP v2c service when it is configured with the default community string
public. By querying standard MIBs (Management Information Bases, which are hierarchical databases used for managing entities in a network), attackers can retrieve the operating system and kernel version, running process names and command-line arguments, network interface configuration, routing table entries, ARP table mappings, active TCP connection details, and file system paths. This allows for detailed reconnaissance of the device and the adjacent network infrastructure.Recommendations
Update Grandstream GWN7660ELR to firmware version 1.0.27.6 or later.
Change the default SNMP community string from
public to a secure value.
Restrict access to the SNMP service to authorized management stations. Found an issue in the description? Have something to add? Feel free to write us 👾