PT-2026-96039

CVE-2026-94142

·

Published

2026-09-21

·

Updated

2026-10-21

Description by

CVSS 3.1
8.8
High
MetricsAV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions BioStar Temperature Monitor Utility version 1.2.1806.2200
Description A write-what-where condition exists in the IOCTL Handler component within the file BS HWMIO64 W10.sys. This issue occurs in the sub 1105C() function when the PhysicalAddress argument is manipulated. Exploitation requires local access to the system.
Recommendations At the moment, there is no information about a newer version that contains a fix for this vulnerability.
Exploitability
Exploit
Impacts
Researchers
Vendors
Affected products
Related identifiers
Found an issue in the description? Have something to add? Feel free to write us 👾